Goosky Legend S1

Goosky S1

Collective-pitch setup with three rotor presets and a six-minute flight timer.

RadioMaster TX16SEdgeTX 2.11.1YML

Made for RadioMaster TX16S. EdgeTX radios (RadioMaster Boxer, TX16S, GX12, Jumper and others) use the same model file format, so this file can be loaded on them. Switches, pots, screens and the internal RF module differ between radios, so check the mixes, switch assignments and RF settings after loading it. A file from newer EdgeTX firmware may not open on an older version. See all EdgeTX radios setups

Imported reference
★Unrated0 ratings
READ FROM THE FILE

Inside this configuration.

EdgeTX YAML

Transmitter input settings only. Output curves, receiver tuning and mechanics may alter the final response.

Model overview 4 rows
SettingValue
Model nameGoosky S1
Firmware formatEdgeTX/OpenTX 2.11.1
RF module 1Multimodule · sub-type 21,0 · channels 1–16 · failsafe custom
RSSI alarms (warning / critical)45 / 42
Inputs (rates & expo) 4 rows

Each line is one input line. Weight is the rate; the curve column shows expo or a custom curve. Lines can be limited to one side of the stick or to flight modes.

InputSourceWeightCurveOffsetSwitchFlight modesSide
AilAil100%Expo 0——AllBoth
EleEle100%Expo 0——AllBoth
ThrThr100%Expo 50——AllBoth
RudRud100%Expo 0——AllBoth
Mixer 10 rows

Mixes are applied top to bottom per channel: = starts a channel, + adds, × multiplies, ← replaces what came before.

ChannelOpSourceWeightOffsetSwitchCurveDelay / slowFlight modesName
CH1=I0100%————All
CH2=I1100%————All
CH3=I2100%—SE↑Curve 1—Allt1
+I2100%—SE–Curve 2—Allt2
+I2100%—SE↓Curve 3—Allt3
CH4=I3100%————All
CH5=MAX-100%—NOT SG↓——Allmode
+MAX100%—SG↓——Allmode
CH6=I2100%—SE↑Curve 4—Allpitch
+I2100%—NOT SE↑Curve 5—All
Outputs (servo limits) 2 rows

Minimum and maximum travel per channel. Channels left at ±100% with no name are hidden.

ChannelNameMinMaxSubtrimDirectionPPM centreCurve
CH1-100%100%—Reversed——
CH4-100%100%—Reversed——
Curves 5 rows
CurveNameTypePointsInterpolationValues (%)
Curve 1t1Fixed X5Lineary: -100, 20, 20, 20, 20
Curve 2t2Fixed X5Lineary: 30, 30, 30, 30, 30
Curve 3t3Fixed X5Lineary: 46, 46, 46, 46, 46
Curve 4p1Fixed X5Lineary: -6, -2, 45, 85, -100
Curve 5p2Fixed X5Lineary: -50, 50, 100
Special functions 1 rows
FunctionSwitchActionParameters
SF1SF↑Override channel2,-100,1
Timers 1 rows
TimerNameModeSwitchStart
Timer 1OnSF↓06:00 countdown
FROM THE COMMUNITY

Experience worth sharing.

0 ratings

Rate the configuration’s usefulness, clarity, and accuracy. Include the equipment you used and what you tested.

Join the community to leave feedback.

Create an account
☆

The conversation starts here.

No community ratings yet. No invented scores.